Simulation collection
Isaac Sim Simulation
Physics-based Franka Panda task trajectories
- Episodes
- 4,785
- Duration
- 32:42:40
- Status
- Active
Simulation trajectories
Inspect the Isaac Sim collection used to train and evaluate Labference agents: synchronized RGB, robot state and action streams at task-specific rates.
Download trajectories, simulation resources and trained policies. Each release documents its compatible code and data versions.
Model releases include the upstream base model, checkpoint or adapter, normalization statistics, camera inputs, action representation and inference instructions. Published evaluation results are listed on the leaderboard.
Download available
Open the Baidu Netdisk share directly or copy the visible link below.
https://pan.baidu.com/s/1zyJL3zxHqI_j67hUkUF6lwSimulation collection
Simulation collection
Physics-based Franka Panda task trajectories
Published simulation tasks
| Task | Episodes | Frames | FPS | Duration |
|---|---|---|---|---|
L12Clear and Reset the Laboratory Bench | 175 | 79,894 | 10 | 7,989 s |
skill:closeClose the laboratory device | 200 | 18,440 | 10 | 1,844 s |
L08NMR Sample Holder Loading | 200 | 28,762 | 10 | 2,876 s |
R09Map a B3 Grid Instruction | 200 | 28,674 | 10 | 2,867 s |
R10Place a Tube at C2 | 200 | 32,253 | 10 | 3,225 s |
R11Locate a Sample-Box Socket | 166 | 5,192 | 10 | 519 s |
L09Load and Start a Laboratory Device | 200 | 98,665 | 10 | 9,866 s |
skill:openOpen the laboratory device | 60 | 8,675 | 10 | 867 s |
L11Operate a Condition Module | 200 | 53,445 | 10 | 5,344 s |
skill:graspPick up the beaker from the table | 400 | 120,932 | 10 | 12,093 s |
skill:stirPick up the glass rod and stir the liquid | 200 | 58,304 | 10 | 5,830 s |
skill:placePick up the object and place it at the target | 200 | 26,821 | 10 | 2,682 s |
skill:pourPick up the source container and pour it into the target container | 200 | 32,318 | 10 | 3,231 s |
L06Sequential Balance Loading | 200 | 83,646 | 10 | 8,364 s |
L02Organize a Vial by Destination | 318 | 57,278 | 10 | 5,727 s |
L01Transport Three Sample Vials | 267 | 137,000 | 10 | 13,700 s |
L10Sequential Three-Vial Loading | 200 | 86,569 | 10 | 8,656 s |
L04Three-Beaker Liquid Mixing | 200 | 118,398 | 10 | 11,839 s |
R08Read and Select an NMR Slot | 200 | 28,671 | 10 | 2,867 s |
R04RPM Adjustment Decision | 104 | 5,749 | 10 | 574 s |
R05State-Dependent Device Control | 200 | 22,668 | 10 | 2,266 s |
R03Temperature-Gated Sample Retrieval | 200 | 20,041 | 10 | 2,004 s |
R03Temperature-Gated Sample Retrieval | 200 | 20,041 | 10 | 2,004 s |
R01Read and Record a Digital Mass | 95 | 5,261 | 10 | 526 s |
HDF5 episode schema
| Field | Type | Purpose |
|---|---|---|
camera_1_rgb / camera_3_rgb | uint8[T,…] | Front and wrist RGB observations |
agent_pose | float32[T,8] | Seven arm joints and gripper state |
actions / actions_ee | float32[T,…] | Next-step joint or end-effector target |
action_gripper | uint8[T] | Binary gripper command: 0 close, 1 open |
display_rgb / weights_rgb | uint8[T,…] | Additional feedback-weighing observations when present |
subtask | UTF-8[T] | Semantic phase annotation aligned to every frame |
timestamp / sim_step | float64 / int64 | Episode time and original 60 Hz physics step |
language_instruction | UTF-8 string | Per-episode task instruction |
task_properties | UTF-8 JSON | Structured task parameters |
attrs: fps / physics_hz / sample_stride | int | Sample rate, source physics rate and decimation step |
Dataset terms
The released Labference dataset may be used, adapted and redistributed with appropriate attribution. Cite Labference and identify whether changes were made.
Read the full Creative Commons Attribution 4.0 International terms →